FM 2105 2x2,3mm - Pt100 thin-film measuring resistor
The FM 2105 is a precise platinum temperature sensor based on advanced thin-film technology. The price quoted refers to the version with Ag5Pd connection wires and tolerance class F 0.3. For alternative configurations, please use the "Ask About Procduct" button.
Resistance at 0°C (R0) |
100 Ω |
Temperature coefficient (0°C up to +100°C) |
3.85 · 10-3 K-1 C-1 |
Tolerance classes according to DIN EN 60751 |
F 0,1 (0°C - +150°C)
F 0,15 (-30°C - +300°C)
F 0,3 (-50°C - +500°C) |
Operating temperature range depending on lead material:
AgPd5, Au-coated Ni-wire
Pt-coated Ni-wire
AuPd5, Pt |
-50 °C up to +400 °C
-50 °C up to +500 °C
(short-time up to +550°C)
-50 °C up to +600 °C |
Measurement current (DC) at 25 °C |
1.0 mA |
Maximal permissible peak current (DC) at 25 °C |
3.0 mA |
Insulation resistance |
> 10 MΩ |
Self-heating at 0 °C |
< 0.4 K / mW |
Thermal response time
Flowing water (v = 0.2 m/s)
Flowing air (v = 1 m/s) |
T0.5 = 0.07s, T0.9 = 0.2s
T0.5 = 4 s, T0.9 = 10 s |
Resistance values [Ω] at Temperature t |
t |
Tolerance class |
F 0,1 [Ω] |
F 0,15 [Ω] |
F 0,3 [Ω] |
0 °C |
100 ± 0.4 |
100 ± 0.6 |
100 ± 1.2 |
+100°C |
138.51 ± 1.0 |
138.51± 1.3 |
138.51 ± 3.0 |
Rt measuring point |
2 mm from wire end |
Maximal Resistance Change at UCT 250 h |
< 0.1 % |
Specification |
DIN EN 60751 |
Type |
Film sensor |
Technology: Advanced thin-film-technology (ceramic carrier with a structured platinum layer, covered with a passivating layer) |
Operating conditions: Unprotected application only in dry environments without any contamination |
Conformity: 2011/65/EU: Restriction of the use of Hazardous Substances Directive (RoHS) |
Dimensions [mm]
|
FMC2105
2x2.3x1.3 |
FMC2105
2x2.3x1.0 |
Leads |
AgPd5 |
NiAu |
NiPt |
Pt |
H1
[mm] |
1.3 ± 0.2 |
1± 0.2 |
l
[mm] |
15 ± 1 |
15 ± 1 |
10 ± 1 |
7 ± 1 |
H2
[mm] |
0.65 |
0.4 |
d
[mm] |
0,25 |
0,2 |
0,2 |
0,2 |