Transmitter LKM410
The LKM410 is an analog transmitter and can be designed for various thermocouples according to DIN EN 60584 and DIN 43710. Its design is ideally suited for mounting in tubular housings. It converts the temperature-dependent thermoelectric voltage of the sensor into a standard signal of 4...20mA. The temperature compensation takes place in the transmitter itself.
The transmitter is supplied calibrated to customer specifications. It can be supplied either with the Hirschmann plug type GSP or without plug. With this arrangement, customer-specific probes with integrated transmitter, such as our Type506, can be realized. By means of span and zero controllers, a subsequent fine adjustment can be carried out on site.
| Thermocouple | Specified range in °C |
|---|---|
| Type B* | 0 – 1820 |
| Type E | -270 – 1000 |
| Type J | -210 – 1200 |
| Type K | -270 – 1372 |
| Type L | -200 – 900 |
| Type N* | -270 – 1340 |
| Type S* | -50 – 1767 |
| Type T | -270 – 400 |
| Type U | -50 – 600 |
| * with higher linearity error | |
| Parameter | Value | Remark |
|---|---|---|
| Input | Thermocouples K, J, L, T, U, E, | N, S, B with higher error |
| Zero point | > -270 °C | depends on thermocouple type |
| Span | > 200 K | depends on thermocouple type |
| Linearity error | < 1% FS | depends on thermocouple type |
| Loop voltage | 10 – 35 VDC | reverse polarity protected |
| Output | 4 – 20 mA | current loop |
| Sensor break | > 20 mA | |
| Sensor short circuit | current value for ambient temperature | |
| Response time | < 0.1 s | |
| TK | < 100 ppm/°C | |
| Operating temperature range | -40 – 85 °C | |
| Humidity | < 95 % | relative humidity |
| Loop connection | Hirschmann connector type GSP | pins 1 (+) and 2 (-) |
| Sensor connection | exposed solder contacts | |
| Optional potting compound | black polyurethane | |
| PCB dimensions | 26 x 15.5 x 12.5 mm | L x W x H |
| Weight | approx. 10 g (unpotted) |
| Document | Format | Language(s) |
|---|---|---|
| Datasheet – LKM410 Technical Specification |
||
| Operating Instructions – LKM410 Installation and operating manual |
| Program / Package | Format | Language(s) |
|---|---|---|
| Program – AnalogToTemperatur Conversion of analog output values (mA or V) to temperature |
ZIP |
{{.}}