The above price is valid for the following geometric dimensions thermocouple type K as well as for accuracy class 2:
Diameter:
6mm
Length:
150mm
Technical data
measuring range
-50...+300°C (depending on thermocouple)
mating
NiCr-Ni (K), Fe-CuNi (J), Cu-CuNi (T) according to DIN EN 60584, Fe-const. (L) acc. to DIN 43710, measuring point not insulated from protective tube
accuracy class
2
Protection tube ød
6mm
Protection tube material
glass
Nominal length NL
NL=150mm (default)
handle
double shell made of PA black (max. 130°C), with anti-kink spring
connecting lead
1.5m PVC-insulated compensating cable with free ends
Options
Connection plug according to specification, transmitter 4..20mA in handle
Ordering information for manual thermocouple probes:
Other diameters and lengths are available on request.
The specified operating temperature range refers to the sensitive part in the measuring tip.
The material-dependent characteristic values (PA max. 130°C, silicone max. 200°C, PTFE max. 250°C) apply to the max. permissible temperature at the handle and the compensating cable.
Standard compensating cable PVC-insulated, length 1.5m with free ends; other lengths and cable types as well as other thermowell lengths and diameters on request; connection ends or plug according to specification